Problems and Resolutions
Problem | Details | Resolution | |
Isolation Fault | Isolation Fault | Grounding fault or surge voltage protection failure |
Check for impedence and potential water (call a solar accredited electrician for this) |
Leakage Detecting | Ground I Fault | Leakage current over rating | Call a solar accredited electrician to check this |
Grid Fault | Fault OVR | AC Over voltage rating | Check grid values |
Fault UVR | AC Under voltage rating | Check grid values | |
Fault OFR | AC Over frequency rating | Check grid values | |
Fault UFR | AC Under frequency rating | Check grid values | |
No Utility | No Utility | No Utility | Check AC is connected and power is on |
Fan Fault | Fan Fault | Fan locked or circuit fault | Clean fan |
PV Over Voltage | PV Over Voltage | PV voltage ≥ Max.DC voltage | Check DC voltage |
Consistent Fault | Consistent Fault | CPU or other circuitry failure | Try re-booting, if not fixed, replace inverter |
Relay Failure | Relay Failure | Relay is failure between grid and inverters |
Try re-booting, if not fixed, replace inverter |
DC INJ High | DC INJ High | DC injection in AC output over rated value. |
Try re-booting, if not fixed, replace inverter |
EEPROM Failure | EEPROM Failure | EEPROM’s failure | Try re-booting, if not fixed, replace inverter |
SCI Failure | SCI Failure | MCU internal communication failure | Try re-booting, if not fixed, replace inverter |
High DC Bus | High DC Bus | DC bus voltage is higher than the set value | Try re-booting, if not fixed, replace inverter |
DC Sensor Fault | DC Sensor Fault | Input DC detector failure | Try re-booting, if not fixed, replace inverter |
GFCI Failure | GFCI Failure | Leakage current detecting circuit failure |
Try re-booting, if not fixed, replace inverter |